6
screws before final tightening. Do not over-tighten.
6b. Cover door plates with decorative plate covers by slid-
ing them from top to bottom on door plates.
Connect Batteries
7. Loosen the #8-32 Phillips pan head screw located on
the rear side of the base plate at the bottom of the lock
(see Fig. 7). Turn counter-clockwise until the battery
cover slides off the housing. Do not remove the screw
completely.
7a. Plug in the battery connector and insert the battery
pack into the battery compartment. Neatly push all wir-
ing inside the compartment. Holding battery in place,
slide cover back on. Secure the battery cover by tight-
ening the #8-32 Phillips pan head screw located on the
rear side of the base plate (access this screw from the
7/16" thru-hole drilled in the door). Do not over tighten
the screw.
8. FOR NEW INSTALLATIONS: Refer to programming
instructions (OI310, OI311 or OI312) for specific in-
structions for "First Time Startup" and "Change Fac-
tory Master Code" before connecting the battery.
The lock must be powered up correctly (and have its
factory Master Code changed) or erratic lock behavior
can result.
Test operation: See next page.
Fig. 6a: Secure lock to door -- loosely at first
Door
Thru-Holes
Door Plate
Fig. 6b: Slide down to install decorative plate covers
Fig. 7: The Phillips screw on the rear side locks or unlocks
the battery cover. Do not remove screw.
Fig. 7a: Install the battery pack: Push all wires inside the battery
compartment and slide plate back on.